1
0
Fork 0
mirror of https://github.com/Ysurac/openmptcprouter-feeds.git synced 2025-02-15 03:51:51 +00:00
openmptcprouter-feeds/luci-mod-admin-full/luasrc/view/admin_system/flashops.htm

96 lines
4.3 KiB
HTML

<%#
Copyright 2008 Steven Barth <steven@midlink.org>
Copyright 2008-2015 Jo-Philipp Wich <jow@openwrt.org>
Licensed to the public under the Apache License 2.0.
-%>
<%+header%>
<h2 name="content"><%:Flash operations%></h2>
<ul class="cbi-tabmenu">
<li class="cbi-tab"><a href="#"><%:Actions%></a></li>
<li class="cbi-tab-disabled"><a href="<%=REQUEST_URI%>/backupfiles"><%:Configuration%></a></li>
</ul>
<fieldset class="cbi-section">
<fieldset class="cbi-section">
<legend><%:Backup / Restore%></legend>
<div class="cbi-section-descr"><%:Click "Generate archive" to download a tar archive of the current configuration files. To reset the firmware to its initial state, click "Perform reset" (only possible with squashfs images).%></div>
<div class="cbi-section-node">
<form class="inline" method="post" action="<%=url('admin/system/flashops/backup')%>">
<input type="hidden" name="token" value="<%=token%>" />
<div class="cbi-value<% if not reset_avail then %> cbi-value-last<% end %>">
<label class="cbi-value-title" for="image"><%:Download backup%>:</label>
<div class="cbi-value-field">
<input class="cbi-button cbi-button-apply" type="submit" name="backup" value="<%:Generate archive%>" />
</div>
</div>
</form>
<% if reset_avail then %>
<form class="inline" method="post" action="<%=url('admin/system/flashops/reset')%>">
<input type="hidden" name="token" value="<%=token%>" />
<div class="cbi-value cbi-value-last">
<label class="cbi-value-title"><%:Reset to defaults%>:</label>
<div class="cbi-value-field">
<input onclick="return confirm('<%:Really reset all changes?%>')" class="cbi-button cbi-button-reset" type="submit" name="reset" value="<%:Perform reset%>" />
</div>
</div>
</form>
<% end %>
</div>
<br />
<div class="cbi-section-descr"><%:To restore configuration files, you can upload a previously generated backup archive here.%></div>
<div class="cbi-section-node">
<form class="inline" method="post" action="<%=url('admin/system/flashops/restore')%>" enctype="multipart/form-data">
<div class="cbi-value cbi-value-last">
<label class="cbi-value-title" for="archive"><%:Restore backup%>:</label>
<div class="cbi-value-field">
<input type="hidden" name="token" value="<%=token%>" />
<input type="file" name="archive" id="archive" />
<input type="submit" class="cbi-button cbi-input-apply" name="restore" value="<%:Upload archive...%>" />
</div>
</div>
</form>
</div>
<% if reset_avail then %>
<div class="alert-message warning"><%:Custom files (certificates, scripts) may remain on the system. To prevent this, perform a factory-reset first.%></div>
<% end %>
</fieldset>
<br />
<fieldset class="cbi-section">
<legend><%:Flash new firmware image%></legend>
<% if upgrade_avail then %>
<form method="post" action="<%=url('admin/system/flashops/sysupgrade')%>" enctype="multipart/form-data">
<input type="hidden" name="token" value="<%=token%>" />
<div class="cbi-section-descr"><%:Upload a sysupgrade-compatible image here to replace the running firmware. Check "Keep settings" to retain the current configuration (requires a compatible firmware image).%></div>
<div class="cbi-section-node">
<div class="cbi-value">
<label class="cbi-value-title" for="keep"><%:Keep settings%>:</label>
<div class="cbi-value-field">
<input type="checkbox" name="keep" id="keep" checked="checked" />
</div>
</div>
<div class="cbi-value cbi-value-last<% if image_invalid then %> cbi-value-error<% end %>">
<label class="cbi-value-title" for="image"><%:Image%>:</label>
<div class="cbi-value-field">
<input type="file" name="image" id="image" />
<input type="submit" class="cbi-button cbi-input-apply" value="<%:Flash image...%>" />
</div>
</div>
</div>
<% if image_invalid then %>
<div class="cbi-section-error"><%:The uploaded image file does not contain a supported format. Make sure that you choose the generic image format for your platform. %></div>
<% end %>
</form>
<% else %>
<div class="cbi-section-descr"><%:Sorry, there is no sysupgrade support present; a new firmware image must be flashed manually. Please refer to the wiki for device specific install instructions.%></div>
<% end %>
</fieldset>
</fieldset>
<%+footer%>