mirror of
				https://github.com/Ysurac/openmptcprouter.git
				synced 2025-03-09 15:40:20 +00:00 
			
		
		
		
	
		
			
				
	
	
		
			150 lines
		
	
	
	
		
			4.5 KiB
		
	
	
	
		
			Diff
		
	
	
	
	
	
			
		
		
	
	
			150 lines
		
	
	
	
		
			4.5 KiB
		
	
	
	
		
			Diff
		
	
	
	
	
	
| From 1fbc2ef71fb116717d1a0f542e56568dfac0181c Mon Sep 17 00:00:00 2001
 | |
| From: Phil Elwell <phil@raspberrypi.com>
 | |
| Date: Wed, 4 Jan 2023 09:14:53 +0000
 | |
| Subject: [PATCH] overlays: i2c-sensor: MS temp & pressure sensors
 | |
| 
 | |
| Add support for the Measurement Specialities temperature and pressure
 | |
| sensors to the i2c-sensor overlay. The supported devices are MS5637,
 | |
| MS5803, MS5805, MS5837 and MS8607.
 | |
| 
 | |
| Signed-off-by: Phil Elwell <phil@raspberrypi.com>
 | |
| ---
 | |
|  arch/arm/boot/dts/overlays/README             | 20 ++++-
 | |
|  .../boot/dts/overlays/i2c-sensor-common.dtsi  | 79 ++++++++++++++++++-
 | |
|  2 files changed, 96 insertions(+), 3 deletions(-)
 | |
| 
 | |
| --- a/arch/arm/boot/dts/overlays/README
 | |
| +++ b/arch/arm/boot/dts/overlays/README
 | |
| @@ -1982,8 +1982,9 @@ Info:   Adds support for a number of I2C
 | |
|          light level and chemical sensors on i2c_arm
 | |
|  Load:   dtoverlay=i2c-sensor,<param>=<val>
 | |
|  Params: addr                    Set the address for the BH1750, BME280, BME680,
 | |
| -                                BMP280, CCS811, DS1621, HDC100X, LM75, SHT3x or
 | |
| -                                TMP102
 | |
| +                                BMP280, CCS811, DS1621, HDC100X, JC42, LM75,
 | |
| +                                MCP980x, MS5637, MS5803, MS5805, MS5837, MS8607,
 | |
| +                                SHT3x or TMP102
 | |
|  
 | |
|          aht10                   Select the Aosong AHT10 temperature and humidity
 | |
|                                  sensor
 | |
| @@ -2044,6 +2045,21 @@ Params: addr                    Set the
 | |
|                                  use the "jc42" option.
 | |
|                                  Valid addresses are 0x18-0x1f (default 0x18)
 | |
|  
 | |
| +        ms5637                  Select the Measurement Specialities MS5637
 | |
| +                                pressure and temperature sensor.
 | |
| +
 | |
| +        ms5803                  Select the Measurement Specialities MS5803
 | |
| +                                pressure and temperature sensor.
 | |
| +
 | |
| +        ms5805                  Select the Measurement Specialities MS5805
 | |
| +                                pressure and temperature sensor.
 | |
| +
 | |
| +        ms5837                  Select the Measurement Specialities MS5837
 | |
| +                                pressure and temperature sensor.
 | |
| +
 | |
| +        ms8607                  Select the Measurement Specialities MS8607
 | |
| +                                pressure and temperature sensor.
 | |
| +
 | |
|          no_timeout              Disable the SMBUS timeout. N.B. Only supported
 | |
|                                  by some jc42 devices - using with an
 | |
|                                  incompatible device can stop it from being
 | |
| --- a/arch/arm/boot/dts/overlays/i2c-sensor-common.dtsi
 | |
| +++ b/arch/arm/boot/dts/overlays/i2c-sensor-common.dtsi
 | |
| @@ -351,6 +351,76 @@
 | |
|  		};
 | |
|  	};
 | |
|  
 | |
| +	fragment@23 {
 | |
| +		target = <&i2cbus>;
 | |
| +		__dormant__ {
 | |
| +			#address-cells = <1>;
 | |
| +			#size-cells = <0>;
 | |
| +			status = "okay";
 | |
| +
 | |
| +			ms5637: ms5637@76 {
 | |
| +				compatible = "meas,ms5637";
 | |
| +				reg = <0x76>;
 | |
| +			};
 | |
| +		};
 | |
| +	};
 | |
| +
 | |
| +	fragment@24 {
 | |
| +		target = <&i2cbus>;
 | |
| +		__dormant__ {
 | |
| +			#address-cells = <1>;
 | |
| +			#size-cells = <0>;
 | |
| +			status = "okay";
 | |
| +
 | |
| +			ms5803: ms5803@76 {
 | |
| +				compatible = "meas,ms5803";
 | |
| +				reg = <0x76>;
 | |
| +			};
 | |
| +		};
 | |
| +	};
 | |
| +
 | |
| +	fragment@25 {
 | |
| +		target = <&i2cbus>;
 | |
| +		__dormant__ {
 | |
| +			#address-cells = <1>;
 | |
| +			#size-cells = <0>;
 | |
| +			status = "okay";
 | |
| +
 | |
| +			ms5805: ms5805@76 {
 | |
| +				compatible = "meas,ms5805";
 | |
| +				reg = <0x76>;
 | |
| +			};
 | |
| +		};
 | |
| +	};
 | |
| +
 | |
| +	fragment@26 {
 | |
| +		target = <&i2cbus>;
 | |
| +		__dormant__ {
 | |
| +			#address-cells = <1>;
 | |
| +			#size-cells = <0>;
 | |
| +			status = "okay";
 | |
| +
 | |
| +			ms5837: ms5837@76 {
 | |
| +				compatible = "meas,ms5837";
 | |
| +				reg = <0x76>;
 | |
| +			};
 | |
| +		};
 | |
| +	};
 | |
| +
 | |
| +	fragment@27 {
 | |
| +		target = <&i2cbus>;
 | |
| +		__dormant__ {
 | |
| +			#address-cells = <1>;
 | |
| +			#size-cells = <0>;
 | |
| +			status = "okay";
 | |
| +
 | |
| +			ms8607: ms8607@76 {
 | |
| +				compatible = "meas,ms8607-temppressure";
 | |
| +				reg = <0x76>;
 | |
| +			};
 | |
| +		};
 | |
| +	};
 | |
| +
 | |
|  	__overrides__ {
 | |
|  		bme280 = <0>,"+0";
 | |
|  		bmp085 = <0>,"+1";
 | |
| @@ -376,11 +446,18 @@
 | |
|  		aht10 = <0>,"+20";
 | |
|  		mcp980x = <0>,"+21";
 | |
|  		jc42 = <0>,"+22";
 | |
| +		ms5637 = <0>,"+23";
 | |
| +		ms5803 = <0>,"+24";
 | |
| +		ms5805 = <0>,"+25";
 | |
| +		ms5837 = <0>,"+26";
 | |
| +		ms8607 = <0>,"+27";
 | |
|  
 | |
|  		addr =  <&bme280>,"reg:0", <&bmp280>,"reg:0", <&tmp102>,"reg:0",
 | |
|  			<&lm75>,"reg:0", <&hdc100x>,"reg:0", <&sht3x>,"reg:0",
 | |
|  			<&ds1621>,"reg:0", <&bme680>,"reg:0", <&ccs811>,"reg:0",
 | |
| -			<&bh1750>,"reg:0", <&mcp980x>,"reg:0", <&jc42>,"reg:0";
 | |
| +			<&bh1750>,"reg:0", <&mcp980x>,"reg:0", <&jc42>,"reg:0",
 | |
| +			<&ms5637>,"reg:0", <&ms5803>,"reg:0", <&ms5805>,"reg:0",
 | |
| +			<&ms5837>,"reg:0", <&ms8607>,"reg:0";
 | |
|  		int_pin = <&max30102>, "interrupts:0";
 | |
|  		no_timeout = <&jc42>, "smbus-timeout-disable?";
 | |
|  	};
 |