1
0
Fork 0
mirror of https://github.com/Ysurac/openmptcprouter.git synced 2025-02-13 20:01:55 +00:00
openmptcprouter/root/target/linux/bcm27xx/patches-5.14/0545-overlays-rpi-poe-plus-Improve-the-cooling-levels.patch
Ycarus (Yannick Chabanois) 5c593832cc Add 5.14 patches for RPI
2021-10-01 16:58:58 +02:00

34 lines
1.1 KiB
Diff

From 328d485a2bea7c2f62e2509f0e31d8432465e5de Mon Sep 17 00:00:00 2001
From: Phil Elwell <phil@raspberrypi.com>
Date: Wed, 18 Aug 2021 17:26:49 +0100
Subject: [PATCH 545/552] overlays: rpi-poe-plus: Improve the cooling levels
The PoE HAT cooling levels are not well suited for the PoE+ HAT - the
fan fails to come on until the temperature reaches the third trip point
(50C).
Give the rpi-poe-plus overlay a different set of cooling levels -
0 32 64 128 255, as suggested by @chris-kai-in.
See: https://github.com/raspberrypi/firmware/issues/1607
Signed-off-by: Phil Elwell <phil@raspberrypi.com>
---
arch/arm/boot/dts/overlays/rpi-poe-plus-overlay.dts | 4 ++++
1 file changed, 4 insertions(+)
diff --git a/arch/arm/boot/dts/overlays/rpi-poe-plus-overlay.dts b/arch/arm/boot/dts/overlays/rpi-poe-plus-overlay.dts
index e0138847093b..5b12d02c3707 100644
--- a/arch/arm/boot/dts/overlays/rpi-poe-plus-overlay.dts
+++ b/arch/arm/boot/dts/overlays/rpi-poe-plus-overlay.dts
@@ -17,3 +17,7 @@ rpi_poe_power_supply: rpi-poe-power-supply@0 {
};
};
};
+
+&fan0 {
+ cooling-levels = <0 32 64 128 255>;
+};
--
2.33.0